RJ Enterprises

Single Phase, Without Battery

Microtek 1KVA Online UPS

  • Capacity: 1KVA / 800W

  • Input Voltage: 230V AC (Single Phase)

  • Input Voltage Range: 110V – 300V AC

  • Output Voltage: 230V ± 1% AC (Single Phase)

  • Battery Voltage: 36V DC

  • Battery Type: External (Typically 3 x 12V Batteries)

  • Backup Time: Depends on battery capacity

  • Waveform: Pure Sine Wave

  • Efficiency: ≥ 90%

Guaranteed Safe Payment
Share

General Specifications:

  • Capacity: 1KVA / 1000VA

  • Topology: Online Double Conversion

  • Phase Configuration: Single Phase Input, Single Phase Output (1PH:1PH)

  • Battery Voltage: 36V DC

Input Specifications:

  • Input Voltage Range: Typically 110V-300V AC (Exact values may vary by brand/model)

  • Input Frequency: 50Hz ± 5Hz or 60Hz ± 5Hz (Auto-sensing)

  • Power Factor: ≥ 0.99 at full load

Output Specifications:

  • Output Voltage: 220V ± 1% (or adjustable as per requirement)

  • Output Frequency: 50Hz / 60Hz (Synchronized with input)

  • Waveform: Pure Sine Wave

  • Transfer Time: 0 ms (True Online UPS)

  • Efficiency: ≥ 90%

Battery & Backup:

  • Battery Configuration: 3 x 12V Batteries (External)

  • Battery Type: Lead-Acid, SMF (Sealed Maintenance-Free)

  • Backup Time: Depends on battery capacity (typically 10-30 minutes on standard configuration)

  • Charging Time: 4-6 hours for 90% charge

Protection Features:

  • Overload Protection

  • Short Circuit Protection

  • Overcharge & Deep Discharge Protection

  • Surge & Spike Protection

Communication & Monitoring:

  • LCD Display for Input/Output Voltage, Battery Level, Load Status, etc.

  • Communication Ports: RS-232 / USB / SNMP (Optional)

Physical & Environmental:

  • Operating Temperature: 0°C – 40°C

  • Humidity: 0 – 95% (Non-condensing)

  • Cooling: Intelligent Fan Cooling System

Brand

Microtek

Specification

Capacity 1KVA/800V
DC Voltage System 36 VDC
No of Battery Required 3 (12V)
Input Voltage Range 110VAC+5% – 300VAC+5%
Frequency Range 40Hz – 70Hz
Phase Single Phase With Ground
Power Factor ≥99 @full Load
Output Voltage 200/ 208/ 220/ 230/ 240VAC
Frequency Range (Battery Mode) 50Hz+0.25Hz OR 60Hz+0.3Hz
Harmonic Distortion <2% THD (Linear Load)
 4% THD (N on-Linear Load)
Overload Capability 105%-110%: Ups Shuts Down After 10 Minutes At Battery Mode Or Transfer To Bypass When The Utility Is Normal.
110%-130%: Ups Shuts Down After 1 Minute At Battery Mode Or Transfer To Bypass When The Utility Is Normal.
>130%: Ups Shuts Down After 3 Seconds At Battery Mode Or Transfer To Bypass When The Utility Is Normal.
Charging Current 1A
Display LDC Display Indication

Reviews

There are no reviews yet.

Be the first to review “Microtek 1KVA Online UPS”

Your email address will not be published. Required fields are marked *